Ericsson EDACS Station GETC1e 19D901868G3 Instrukcja Instalacji

Przeglądaj online lub pobierz Instrukcja Instalacji dla Zdalne rozruszniki Ericsson EDACS Station GETC1e 19D901868G3. Ericsson EDACS Station GETC1e 19D901868G3 Installation manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Configuration Manual

LBI-38988BConfiguration ManualEDACS Station GETC1e19D901868G3 and G4

Strona 2 - REVISION HISTORY

LBI-38988 SOFTWARE COMPATIBILITY10 Rev. BRADIO COMPATIBILITYTable 3 describes the minimum software requirementsfor radio products supporting the featu

Strona 3

HARDWARE COMPATIBILITY LBI-38988Rev. B 11HARDWARE COMPATIBILITYThe GETC hardware compatibility depends on theversion of EPROM installed on the Logic B

Strona 4

LBI-38988 DESCRIPTION12 Rev. BDESCRIPTIONThe Station GETC is the foundation of all EDACStrunking operations. It is capable of operating in theTrunke

Strona 5

LBI-38988Rev. B 13whenever the communications between the Site Controllerand the Control Channel GETC is lost.STATION CONTROLThe Station GETC controls

Strona 6 - SOFTWARE FEATURES

LBI-38988 CONFIGURATION14 Rev. BCONFIGURATIONThe configuration process involves the followingprocedures and should be completed in the order presented

Strona 7 - SOFTWARE FEATURES LBI-38988

CONFIGURATION LBI-38988Rev. B 15Rockwell Modem InstallationThe Rockwell Modem provides a high speedsynchronous serial interface between the Station G

Strona 8 - LBI-38988 SOFTWARE FEATURES

LBI-38988 CONFIGURATION16 Rev. BS4S3S2S1L1 L2 L3 L4 L5L6L7T1 T2U18R11111U19U3U2U1J3J49J27J10J9 J8 J6 J19J7TP107LED IndicatorsDip SwitchesReset SwitchR

Strona 9 - SOFTWARE COMPATIBILITY

CONFIGURATION LBI-38988Rev. B 17GETC SOFTWARE INSTALLATIONThe GETC software installation procedure involvesinstalling the latest version of the EPROM

Strona 10 - RADIO COMPATIBILITY

LBI-38988 CONFIGURATION18 Rev. Bthis manual and the detailed instructions containedin TQ-3357 and SRN1060.15. Perform an operational checkout using t

Strona 11 - HARDWARE COMPATIBILITY

CONFIGURATION LBI-38988Rev. B 19Satellite Receivers & Simulcast Remote TXPerform the following steps when installing thesoftware in a GETC connect

Strona 12 - OPERATION

LBI-389882 Rev. BNOTICE!This manual covers Ericsson and General Electric products manufactured and sold by Ericsson Inc.NOTICE!Repairs to this equipme

Strona 13 - LBI-38988

LBI-38988 CONFIGURATION20 Rev. BDe-installing The GETC-1e SoftwareIf a problem arises while upgrading or installing thenew software, it may be necessa

Strona 14 - CONFIGURATION

CONFIGURATION LBI-38988Rev. B 21PC Programmer SetupPrepare the PC for programming the GETC TurboBoard by performing the following steps:TQ-3357 V4.03

Strona 15 - CONFIGURATION LBI-38988

LBI-38988 CONFIGURATION22 Rev. Bof the serial cable to the GETC Shelf connectorJ100, see Figure 5.2. Set the GETC DIP switches S1, S2, and S3 for th

Strona 16 - LBI-38988 CONFIGURATION

CONFIGURATION LBI-38988Rev. B 233. Verify that front panel LEDs L6 and L7 areflashing, as shown in Table 6. This indicates theGETC is ready for prog

Strona 17

LBI-38988 CONFIGURATION24 Rev. BTable 7 - Sample Station PersonalityPersonality: C:\GE\GTC\PERS\SAMPLE.GTC~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

Strona 18

CONFIGURATION LBI-38988Rev. B 25Table 7 - Sample Station Personality (Continued)CONFIRMED CALL ENABLES STATUS: Clear Voice Digital V

Strona 19

LBI-38988 OPERATIONAL CHECKOUT26 Rev. BOPERATIONAL CHECKOUTVerify that the GETC is operating correctly byperforming the following steps:DIP Switch Se

Strona 20

OPERATIONAL CHECKOUT LBI-38988Rev. B 272. Place test calls from radios in Channel Test bykeying one of the test radios and monitoring theaudio from

Strona 21

LBI-38988 OPERATIONAL CHECKOUT28 Rev. B Table 12 - LED Indicators for Failsoft AssignedChannelsLED Indicators L1 L2 L3 L4 L5 L6 L7Failsoft Assigned WB

Strona 22

TROUBLESHOOTING LBI-38988Rev. B 29TROUBLESHOOTINGThe hardware used in the GETC is extremely reliable,making component failure the unlikely cause of mo

Strona 23

LBI-38988Rev. B 3TABLE OF CONTENTSPageREVISION HISTORY...

Strona 24

LBI-38988 TROUBLESHOOTING30 Rev. BTable 15 - Interface Status During Various StatesSIGNAL STATE STATUSControl Channel:Vol/Sq (J7-2) Data High Speed si

Strona 25

TROUBLESHOOTING LBI-38988Rev. B 31Table 15 - Interface Status During Various States (Continued)SIGNAL STATE STATUSWorking Channel (Active): Handshake

Strona 26 - OPERATIONAL CHECKOUT

LBI-38988 TROUBLESHOOTING32 Rev. BTable 15 - Interface Status During Various States (Continued)SIGNAL STATE STATUSWorking Channel (Active): During Di

Strona 27 - Failsoft System

INTERCONNECT DIAGRAMS LBI-38988Rev. B 33 1J8P8321645P1946J1946FSLP6J689678967321 321P3 J 3 P2 J 2213213P1 XU3J10 P102121J27 P1123456123456213213J3Roc

Strona 28 - INTERFACE SIGNALS

LBI-38988B INTERCONNECT DIAGRAMS34 Rev. BMASTR III STATION INTERCONNECT

Strona 29 - TROUBLESHOOTING

LBI-38988Rev. B 35DelayPTTTXMODCGHIPTTEXTREPEATER STATION36+-J801161161J6P262 9 15142 9 1514J7P2755J19P19P/O Harness19C320811GETCPOWER SUPPLY44VOL/SQ

Strona 30 - LBI-38988 TROUBLESHOOTING

LBI-38988B36 Rev. BGETC CABLE19C336863G1SYMBOL PARTNUMBERDESCRIPTION------------------ JACKS ------------------J100thruJ10219B209727P18 Connector: 9

Strona 31 - TROUBLESHOOTING LBI-38988

LBI-38988Rev. B 37GETC CABLE19C336863G1(19C336863, Sh. 1, Rev. 4; 19C336866, Sh. 1, Rev. 0)

Strona 32

LBI-38988B38 Rev. BThis page intentionally left blank

Strona 33 - INTERCONNECT DIAGRAM

800 MHZ FREQUENCY SELECTIONS LBI-38988Rev. B A-1APPENDIX A800 MHZ EDACS APPLICATIONSFREQUENCY SELECTIONSGETC DIP SWITCH SETTINGSNOTEFor MASTR II/IIe u

Strona 34 - 34 Rev. B

LBI-389884 Rev. BTABLE OF CONTENTSPageDIP Switch Settings...

Strona 35

LBI-38988 800 MHZ FREQUENCY SELECTIONSA-2 Rev. BS1-1 S2-1 S1-1 S2-1 S1-1 S2-1TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru(MHz) S1-7 S2-4 (MHz

Strona 36 - LBI-38988B

800 MHZ FREQUENCY SELECTIONS LBI-38988Rev. B A-3S1-1 S2-1 S1-1 S2-1 S1-1 S2-1TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru(MHz) S1-7 S2-4 (MHz

Strona 37

LBI-38988 800 MHZ FREQUENCY SELECTIONSA-4 Rev. BS1-1 S2-1 S1-1 S2-1 S1-1 S2-1TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru(MHz) S1-7 S2-4 (MHz

Strona 38

800 MHZ FREQUENCY SELECTIONS LBI-38988Rev. B A-5S1-1 S2-1 S1-1 S2-1 S1-1 S2-1TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru(MHz) S1-7 S2-4 (MHz

Strona 39 - GETC DIP SWITCH SETTINGS

LBI-38988 800 MHZ FREQUENCY SELECTIONSA-6 Rev. BS1-1 S2-1 S1-1 S2-1 S1-1 S2-1TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru(MHz) S1-7 S2-4 (MHz

Strona 40 - S1-1 S2-1 S1-1 S2-1 S1-1 S2-1

800 MHZ FREQUENCY SELECTIONS LBI-38988Rev. B A-7S1-1 S2-1 S1-1 S2-1 S1-1 S2-1TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru(MHz) S1-7 S2-4 (MHz

Strona 41

LBI-38988 800 MHZ FREQUENCY SELECTIONSA-8 Rev. BS1-1 S2-1 S1-1 S2-1 S1-1 S2-1TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru(MHz) S1-7 S2-4 (MHz

Strona 42

800 MHZ FREQUENCY SELECTIONS LBI-38988Rev. B A-9S1-1 S2-1 S1-1 S2-1 S1-1 S2-1TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru(MHz) S1-7 S2-4 (MHz

Strona 43

LBI-38988 800 MHZ FREQUENCY SELECTIONSA-10 Rev. BS1-1 S2-1 S1-1 S2-1 S1-1 S2-1TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru(MHz) S1-7 S2-4 (MH

Strona 44

800 MHZ FREQUENCY SELECTIONS LBI-38988Rev. B A-11S1-1 S2-1 S1-1 S2-1 S1-1 S2-1TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru(MHz) S1-7 S2-4 (MH

Strona 45

LBI-38988Rev. B 5LIST OF TABLESPageTable 1 - GETC EPROM and Turbo Software Compatibility...9Table 2 - EDAC

Strona 46

LBI-38988 800 MHZ FREQUENCY SELECTIONSA-12 Rev. BS1-1 S2-1 S1-1 S2-1 S1-1 S2-1TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru(MHz) S1-7 S2-4 (MH

Strona 47

800 MHZ FREQUENCY SELECTIONS LBI-38988Rev. B A-13S1-1 S2-1 S1-1 S2-1 S1-1 S2-1TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru(MHz) S1-7 S2-4 (MH

Strona 48

LBI-38988 800 MHZ FREQUENCY SELECTIONSA-14 Rev. BS1-1 S2-1 S1-1 S2-1 S1-1 S2-1TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru(MHz) S1-7 S2-4 (MH

Strona 49

Rev. B B-1900 MHZ FREQUENCY SELECTIONS LBI-38988APPENDIX B900 MHZ EDACS APPLICATIONSFREQUENCY SELECTIONSGETC DIP SWITCH SETTINGSNOTEFor MASTR II/IIe u

Strona 50

LBI-38988 900 MHZ FREQUENCY SELECTIONSB-2 Rev. BS1-1 S2-1 S1-1 S2-1 S1-1 S2-1TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru(MHz) S1-7 S2-4 (MHz

Strona 51

900 MHZ FREQUENCY SELECTIONS LBI-38988Rev. B B-3S1-1 S2-1 S1-1 S2-1 S1-1 S2-1TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru(MHz) S1-7 S2-4 (MHz

Strona 52

LBI-38988 900 MHZ FREQUENCY SELECTIONSB-4 Rev. BS1-1 S2-1 S1-1 S2-1 S1-1 S2-1TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru(MHz) S1-7 S2-4 (MHz

Strona 53 - 900 MHZ EDACS APPLICATIONS

900 MHZ FREQUENCY SELECTIONS LBI-38988Rev. B B-5S1-1 S2-1 S1-1 S2-1 S1-1 S2-1TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru(MHz) S1-7 S2-4 (MHz

Strona 54

LBI-38988Ericsson Inc.Private Radio SystemsMountain View RoadLynchburg, Virginia1-800-528-7711 (Outside USA, 804-528-7711) Printed in U.S.A.

Strona 55

LBI-38988 INTRODUCTION6 Rev. BINTRODUCTIONThis manual provides instructions for configuring theEricsson GE Trunking Card Shelf (GETC), part number19D

Strona 56

SOFTWARE FEATURES LBI-38988Rev. B 7• Receive Adjacency information from the SiteController or Downlink.• Count the number of actual Adjacent Systems

Strona 57

LBI-38988 SOFTWARE FEATURES8 Rev. Bcapability of listening to both the IMC and the Votersimultaneously.For a Simulcast system, no additional equipme

Strona 58 - Printed in U.S.A

RELATED PUBLICATIONS LBI-38988Rev. B 9RELATED PUBLICATIONSIt may be necessary to consult one or more of thefollowing documents during the installation

Komentarze do niniejszej Instrukcji

Brak uwag