31
Status Inputs and Outputs
Board LEDs
General Purpose CPU FAIL, STATUS, RUN, and SCON
MIC RUN, FAIL, and STATUS
PRI-48 RUN, FAIL, TRUNK A alarm, and Trunk B alarm
PRI-64 RUN, FAIL, TRUNK A alarm, Trunk B alarm, and 7-Segment Self-
Test Display
Drive LEDs Disk activity lamps on both drives
Fan LED 12 VDC power indicator lamp
Remote Reset Input Connector Shorting two pins forces a system RESET
Environmental
The operating environment must be free of corrosives or contaminants such as salt water or excessive dust. The
following environmental specifications should be met:
Temperature
Operating 0 to +40°C
Non-Operating -20 to 85°C
Humidity 20 to 90% noncondensing (except for removable diskette drive)
Storage Temperature -40 to +85°C
Operating Altitude < 15,000'
Shipping Altitude < 50,000'
Diagnostics
Error Detection Run-time errors logged in a file for viewing or printing
System Configuration Configuration files can be viewed from the VT100 terminal interface
using “config -f”
Controlled Shutdown System operator can produce a graceful system shutdown so that calls
in progress are completed
4.2. AUDIO MULTIPLEXER
4.2.1. T1 MUX Specifications
The NEC MUX will be used for T1 applications. Its specifications are as follows:
T1 - 23 B+D
Configured w/ 4...23 cards*
Mechanical Construction
19.2" x 19" x 12"
Weight
<59.6 lb
Power Requirements
Voltage -44 to -56V DC (-48V nominal)
Power Consumption 34W (0.7A)
Environmental Requirements
Temperature 4.4 to 38°C
Humidity 20 to 55% (without condensations)
*Must have card for each audio line